- SZK PH2 VDE
- SZK PH1 VDE: Phillips screwdriver PH1 with VDE insulation
- Pliers UNIFOX-C VDE
- Stripping WIREFOX 2.5
- Stripper WIREFOX 4
- Screwdriver SZS 0.4X2.5 VDE
- Screwdriver SF-SL 0.6×3.5–100
- Screwdriver SF-SL 0.4×2.5–75
- Screwdriver SF-PH2-100
- Screwdriver SZS 0.6×3.5 VDE
- Screwdriver SF-PH1-80
- Tool set SF-M
- Stripping tool WIREFOX 6SC
- Automatic stripper WIREFOX 10
- Cable stripping WIREFOX-D 28
- Electronic cutters MICROFOX SP-1
- Diagonal cutter MICROFOX-S ESD
- Cutter CUTFOX-S VDE
- Cutter CUTFOX-CD
- Cutter CUTFOX-ES
- Cutter CUTFOX 12
- CRIMPFOX CENTRUS 10S
- UT10 terminal block
- UT6 terminal block
- UT4 TWIN terminal block
- UT4 QUATTRO terminal block
- UT4 terminal block
- UT2.5 TWIN terminal block
- UK6N terminal block
- UT2.5 QUATTRO terminal block
- UT2.5 terminal block
- UK10N terminal block
- UK2.5N terminal block
- ST6 terminal block
- ST4-TWIN terminal block
- ST4-QUATTRO terminal block
- ST4 terminal block
- ST2.5-TWIN terminal block
- ST2.5 QUATTRO terminal block
- ST2.5 terminal block
- PT6 terminal block
- PT 4-TWIN terminal block
- PT 4 terminal block
- PT 2.5-TWIN terminal block
- PT 2.5-QUATTRO terminal block
- PT 2.5 terminal block
- Cable YSLYSY-JZ 18×0.75
- Cable YSLYSY-JZ 12×0.75
- Cable YSLYSY-JZ 7×0.75
- Cable YSLYSY-JZ 5×0.75
- Cable YSLYSY-JZ 3×0.75
- Cable YSLY-OZ 7×0.75
- Cabel YSLY-OZ 5×0.75
- Cable YSLY-OZ 3×0.5
- Cable YSLY-OZ 2×0.5
- Cabel YSLCY-JZ 7×0.75
- Cable YSLCY-JZ 5×0.75
- Cable YSLCY-JZ 3×0.75
- Cable HSLCH-OZ 2×0.75
- Cable HSLCH-JZ 7×0.75
- Cable HSLCH-JZ 5×0.75
- Cable HSLCH-JZ 3×0.75 GY
- Cable H07V-K 1×50
- Cable H07V-K 1×35
- Cable H07V-K 1×25
- Cable H07V-K 1×16
- Cable H07V-K 1×10
- Cabel H07V-K 1×1.5
- Cable H07V-K 1×6
- Cable H07V-K 1×4
- Cable H07V-K 1×2.5
- Cable H07RN-F 7G2.5
- Cable H07RN-F 7G1.5
- Cable H07RN-F 5G4
- Cable H07RN-F 5G2.5
- Cable H07RN-F 5G1.5
- Cable H07RN-F 4G16
- Cable H07RN-F 4G10
- Cable H07RN-F 4G6
- Cable H07RN-F 4G4
- Cable H07RN-F 4G2.5
- Cable H07RN-F 4G1.5
- Cable H07RN-F 3G10
- Cable H07RN-F 3G6
- Cable H07RN-F 3G4
- Cable H07RN-F 3G2.5
- Cable H07RN-F 3G1.5
- Cable H07RN-F 2X6
- Cable H07RN-F 2X4 BK
- Cable H07RN-F 2X2.5
- Cable H07RN-F 2X1.5
- Cable H05VV-F PVC 3X2.5
- Cable H05VV-F PVC 3X1.5
- Cable H05VV-F PVC 3X1.0
- Cable H05VV-F PVC 3X0.75
- Cable H05VV-F PVC 2X2.5
- Cable H05VV-F PVC 2X1,5
- Cable H05VV-F PVC 2X1,0
- Cable H05VV-F 2X0.75
- Wire H05V-K 1X1
- Wire H05V-K 1X0,75
- Wire H05V-K 1X0.5
The T-T Electric LAKC is the manufacturer’s heavy-industrial DC motor range, comprising fully laminated, compensated shunt-wound motors in 4- and 6-pole configurations across frame sizes 355 to 560 mm (and, per the manufacturer’s product literature, extending further into the range’s largest frames on request). Catalogued outputs run from roughly 300 kW up to 1300 kW, with torque from 4,000 to 23,000 Nm.
Construction is built around a fully laminated stator yoke with main poles and interpoles, and — distinctively for this range — a pole-face compensation winding that enhances performance under overload conditions and preserves excellent commutation across the full speed range. Armatures are vacuum-impregnated with 100% resin fill for reliability, mounted on generously dimensioned shafts and bearings, with square-design end shields that give easy access to the brushes for inspection and maintenance.
Insulation is class H with temperature rise limited to class F. The range is available in several cooling forms — force or pipe ventilated at IP23, double-pipe ventilated, air-air or air-water cooled at IP54, with IP55 available as a special protection option — and in horizontal or vertical, foot or flange mounting forms, including a two-shaft-end variant for tandem use.
Standard duty is S1 (continuous) with an overload capability of 160% full-load torque for 15 seconds every 5 minutes, or 200% full-load current for 30 seconds every 15 minutes — headroom built for the repetitive, high-inertia loads typical of heavy industry. Because each LAKC motor is custom-built to the requirements of its application, exact performance figures (power, current, torque at each operating point) are configured and confirmed with the manufacturer for every project; the mechanical data below — frame, pole configuration, rotor inertia and maximum speed — reflects the manufacturer’s own published range structure.
In a heavy-duty drive system, the LAKC motor is the machine that must reliably convert very high DC power into shaft torque under continuous, demanding duty — its compensated windings and reinforced thermal design are what make that possible without sacrificing commutation quality.
The LAKC range is used across the most demanding heavy-industrial applications:
Steel and Metal Rolling Mills
The compensated winding and high overload capacity suit the continuous, high-torque, cyclic loading found in rolling mill main drives and auxiliary equipment.
Mining and Mineral Processing
Robust construction and a wide choice of protection classes make the LAKC suitable for hoists, mills and other heavy mineral-processing drives.
Marine Propulsion and Offshore Equipment
The range’s mechanical robustness and available cooling options support demanding marine and offshore drive applications.
Paper and Heavy Process Industry
Large paper machines and other continuous-process lines benefit from the range’s high thermal time constant and stable commutation at sustained high loads.
Because the LAKC range is engineered and configured per project, T-T Electric confirms the exact technical parameters — power, current, torque, and cooling arrangement — for each application individually; the data in this package reflects the manufacturer’s published range structure and general specifications.
| Type | Number of Poles | Frame Size, mm | Stack Length | Rotor Inertia, kg·m² | Maximum Speed, rpm |
| LAKC 4355 A | 4 | 355 | A | 14.3 | 1800 |
| LAKC 4355 B | 4 | 355 | B | 15.8 | 1800 |
| LAKC 4355 C | 4 | 355 | C | 17.3 | 1800 |
| LAKC 6400 A | 6 | 400 | A | 23.0 | 1750 |
| LAKC 6400 B | 6 | 400 | B | 28.8 | 1750 |
| LAKC 6400 C | 6 | 400 | C | 36.3 | 1750 |
| LAKC 4450 A | 4 | 450 | A | 47.1 | 1600 |
| LAKC 4450 B | 4 | 450 | B | 53.0 | 1600 |
| LAKC 4450 C | 4 | 450 | C | 59.7 | 1600 |
| LAKC 6500 A | 6 | 500 | A | 69.5 | 1500 |
| LAKC 6500 B | 6 | 500 | B | 87.1 | 1500 |
| LAKC 6500 C | 6 | 500 | C | 109.8 | 1500 |
| LAKC 6500 D | 6 | 500 | D | 127.0 | 1500 |
| LAKC 6560 A | 6 | 560 | A | 145.0 | 1250 |
| LAKC 6560 B | 6 | 560 | B | 165.0 | 1250 |
| LAKC 6560 C | 6 | 560 | C | 187.5 | 1250 |
| LAKC 6560 D | 6 | 560 | D | 207.5 | 1250 |