Danfoss iC2-Micro in Stock: Fast Replacement for Mitsubishi Drives
ic2_Mitsubishi analog

Danfoss iC2-Micro in Stock: Fast Replacement for Mitsubishi Drives

In industrial applications, a variable frequency drive rarely fails when you have several weeks to wait for a replacement. At Technosens, Danfoss iC2-Micro drives are available from stock, allowing us to quickly select suitable replacements for a range of Mitsubishi Variable Frequency Drives used on conveyors, pumps, fans, packaging equipment, mixers, and other industrial machinery. Mitsubishi drives are particularly common in imported machinery that has been operating at industrial facilities for many years.

Mitsubishi → Danfoss iC2-Micro Cross-Reference

Mitsubishi 247595 FR-D720S-008SC-EC 132L6110 IC2-30FA1N02-02A2E20F0+ACXX
Mitsubishi 247596 FR-D720S-014SC-EC 132L6110 IC2-30FA1N02-02A2E20F0+ACXX
Mitsubishi 247597 FR-D720S-025SC-EC 132L6110 IC2-30FA1N02-02A2E20F0+ACXX
Mitsubishi 247598 FR-D720S-042SC-EC 132L6111 IC2-30FA1N02-04A2E20F0+ACXX
Mitsubishi 247599 FR-D720S-070SC-EC 132L6112 IC2-30FA1N02-06A8E20F0+ACXX
Mitsubishi 247600 FR-D720S-100SC-EC 132L6115 IC2-30FA1N02-09A6E20F0+ACXX
Mitsubishi 261963 FR-D740-022-E11 132L6129 IC2-30FA3N04-02A2E20F2+ACXX
Mitsubishi 261964 FR-D740-036-E11 132L6130 IC2-30FA3N04-03A7E20F2+ACXX
Mitsubishi 261965 FR-D740-050-E11 132L6131 IC2-30FA3N04-05A3E20F2+ACBC
Mitsubishi 261966 FR-D740-080-E11 132L6133 IC2-30FA3N04-09A0E20F2+ACBC
Mitsubishi 261967 FR-D740-120-E11 132L6134 IC2-30FA3N04-12A0E20F2+ACBC
Mitsubishi 261968 FR-D740-160-E11 132L6135 IC2-30FA3N04-15A5E20F2+ACBC
Mitsubishi 261969 FR-D740-230-E11 132L6136 IC2-30FA3N04-23A0E20F2+ACBC
Mitsubishi 261970 FR-D740-295-E11 132L6137 IC2-30FA3N04-31A0E20F2+ACBC

An important point: a replacement drive should never be selected by power rating alone. The motor rated current, supply voltage, load characteristics, control signals, Modbus communication, and any other functions used by the machine must also be checked. If you need an urgent replacement for a Mitsubishi drive, send us a photo of the VFD and motor nameplates. We will verify compatibility and select the appropriate Danfoss iC2-Micro model available from stock.