An extrusion line can remain in operation for decades. In many cases, its mechanical components — the frame, gearbox, screw and barrel — are still perfectly serviceable, while problems begin to arise in the drive system.
This is particularly common with older machines designed around DC motors and thyristor DC drives. When the motor has already been repaired several times, the commutator and brush assembly are wearing out, and spare parts for the drive are becoming increasingly difficult to source, replacing the entire machine may seem like the obvious next step. But a new extruder is not always the only option. If the mechanical system still has significant service life remaining, it may make more sense to keep the existing extruder and modernize its drive system: replace the old DC motor with a modern AC motor controlled by a Variable Frequency Drive (VFD).
Industrial facilities still operate extrusion lines from different generations of manufacturers such as KraussMaffei, battenfeld-cincinnati, Davis-Standard, Coperion, Bausano, and others. These manufacturers continue to produce extruders and complete lines for profile, pipe and sheet extrusion, as well as compounding applications. The age of an extrusion line alone is therefore not a reason to replace it.
What Does a DC-to-AC Retrofit Actually Involve?
A DC-to-AC retrofit is not simply a matter of removing one motor and installing another in its place. A properly engineered retrofit requires an assessment of the entire drive system: the existing DC motor, thyristor drive, gearbox, mechanical coupling, control system, and the machine’s actual operating conditions. The modernization may include removing the existing DC drive, selecting an appropriate AC induction motor, installing a VFD, mechanically adapting the new motor to the gearbox, upgrading the control cabinet, and integrating the new drive into the existing automation system. Where required, an encoder or separately powered motor cooling system can also be added.
The main objective is not to rebuild the entire machine, but to preserve as much of the existing mechanical system as possible while it remains in good operating condition.
A similar approach is used at major European manufacturing facilities. In 2026, Danfoss published a case study describing the modernization of extrusion lines at Mitsubishi Chemical Advanced Materials in Belgium. During the retrofit, the existing machine mechanics were retained, while the frame and belt drive were adapted to accommodate the new motor and the electrical drive system was modernized.
Why an Extruder Retrofit Cannot Be Engineered “by Kilowatts”
One of the most common mistakes is to look at the nameplate of the existing motor and conclude: “The old motor was 100 kW, so we need a new 100 kW motor and a 100 kW VFD.” For an extruder, that is not enough. Extrusion applications often require high torque at low speed. This is also one of the challenges highlighted by Danfoss in the MCAM project: low-speed, high-torque operation places much greater demands on motor control than a typical fan application. The actual operating point therefore needs to be analyzed: screw speed, gearbox ratio, required torque, maximum motor speed, starting overload requirements, and how long the motor operates at low speed. Motor cooling is another important consideration. On a standard AC induction motor, the cooling fan is mounted on the motor shaft. When the VFD reduces motor speed, fan speed — and therefore cooling capacity — decreases as well. At the same time, an extruder may still require high torque. For this reason, extrusion applications often use separately powered forced ventilation, allowing the motor cooling system to operate independently of the motor shaft speed.
An Encoder Is Not Always Necessary
In the past, an encoder was often considered almost essential for accurate motor control at low speeds. Modern VFDs can eliminate the need for one in many applications. In the MCAM project, the Danfoss iC7-Automation was able to provide stable control of the extruder motor at high torque and low speed in open-loop operation — without an encoder. According to Danfoss, following the drive replacement, the line was commissioned at full torque in less than four hours. This does not mean that encoders are no longer required. If the process requires highly stable low-speed operation, precise torque control, or closed-loop vector control, motor feedback may still be necessary. Whether an encoder is required should therefore be determined for the specific machine and application rather than specified simply out of habit.
What If a Standard AC Motor Does Not Fit?
In practice, this can be one of the most challenging parts of an extruder retrofit. Older DC motors may have very different mechanical dimensions: shaft height, frame width, mounting feet, flange dimensions, shaft length and shaft diameter. As a result, a standard IEC motor with the same power rating may simply not fit into the available space. In these cases, we can consider square-frame AC motors — AC induction motors with a mechanical form factor that is much closer to traditional industrial DC machines. For these applications, Technosens can use TT Electric AMP square-frame AC motors. This makes it possible to select a mechanical configuration closer to the existing drive and, in some cases, avoid major modifications to the machine frame, gearbox, or complete drive assembly. This is where a retrofit delivers the greatest value: instead of forcing a standard motor into an existing machine at any cost, the drive system is engineered around the mechanical equipment already installed at the facility.
What Does the Facility Keep After the Retrofit?
If the mechanical components of the extruder remain in good condition, they stay in operation. The facility keeps the: extruder, gearbox, screw, barrel, and process equipment.
What changes are the components that have become problematic:
DC motor → AC motor
thyristor DC drive → modern Variable Frequency Drive
and, where necessary:
legacy control system → modern automation system
For motor control, solutions such as the Danfoss VLT® AutomationDrive FC 302 or the newer Danfoss iC7-Automation can be considered. The final selection depends on power and torque requirements, speed range, encoder requirements, communication interfaces, and the operating requirements of the machine itself. There is one important point here: we do not recommend replacing a DC drive simply because it is old. If the machine is operating reliably, the existing DC architecture can still be maintained, and repairs remain economically justified, there may be no reason to replace it. However, when the motor, thyristor drive and control system are all ageing at the same time, the cost of each subsequent repair should be compared with the cost of a complete conversion to an AC drive system.
When Is It Worth Evaluating a Retrofit?
A retrofit becomes particularly worth considering when the DC motor has already been repaired several times, commutator problems are becoming more frequent, drive spare parts are increasingly difficult to source, and extruder downtime is becoming more expensive than the repair itself. Especially when the mechanical system is still in good operating condition. At that point, the question does not necessarily have to be:
“How much will a new extrusion line cost?”
A better question may be:
“How much longer could our existing line operate if we replaced its weakest point — the drive system?”
Technosens can assess the existing DC drive system, select an appropriate AC motor and VFD, design the control cabinet, and carry out commissioning. For an initial assessment, we can start with photos of the motor and drive nameplates, an overall photo of the existing drive assembly, and the main technical data of the machine. Sometimes a facility does not need a new extruder at all. It needs a new drive system for the extruder it already has.