- SZK PH2 VDE
- SZK PH1 VDE: Phillips screwdriver PH1 with VDE insulation
- Pliers UNIFOX-C VDE
- Stripping WIREFOX 2.5
- Stripper WIREFOX 4
- Screwdriver SZS 0.4X2.5 VDE
- Screwdriver SF-SL 0.6×3.5–100
- Screwdriver SF-SL 0.4×2.5–75
- Screwdriver SF-PH2-100
- Screwdriver SZS 0.6×3.5 VDE
- Screwdriver SF-PH1-80
- Tool set SF-M
- Stripping tool WIREFOX 6SC
- Automatic stripper WIREFOX 10
- Cable stripping WIREFOX-D 28
- Electronic cutters MICROFOX SP-1
- Diagonal cutter MICROFOX-S ESD
- Cutter CUTFOX-S VDE
- Cutter CUTFOX-CD
- Cutter CUTFOX-ES
- Cutter CUTFOX 12
- CRIMPFOX CENTRUS 10S
- UT10 terminal block
- UT6 terminal block
- UT4 TWIN terminal block
- UT4 QUATTRO terminal block
- UT4 terminal block
- UT2.5 TWIN terminal block
- UK6N terminal block
- UT2.5 QUATTRO terminal block
- UT2.5 terminal block
- UK10N terminal block
- UK2.5N terminal block
- ST6 terminal block
- ST4-TWIN terminal block
- ST4-QUATTRO terminal block
- ST4 terminal block
- ST2.5-TWIN terminal block
- ST2.5 QUATTRO terminal block
- ST2.5 terminal block
- PT6 terminal block
- PT 4-TWIN terminal block
- PT 4 terminal block
- PT 2.5-TWIN terminal block
- PT 2.5-QUATTRO terminal block
- PT 2.5 terminal block
- Cable YSLYSY-JZ 18×0.75
- Cable YSLYSY-JZ 12×0.75
- Cable YSLYSY-JZ 7×0.75
- Cable YSLYSY-JZ 5×0.75
- Cable YSLYSY-JZ 3×0.75
- Cable YSLY-OZ 7×0.75
- Cabel YSLY-OZ 5×0.75
- Cable YSLY-OZ 3×0.5
- Cable YSLY-OZ 2×0.5
- Cabel YSLCY-JZ 7×0.75
- Cable YSLCY-JZ 5×0.75
- Cable YSLCY-JZ 3×0.75
- Cable HSLCH-OZ 2×0.75
- Cable HSLCH-JZ 7×0.75
- Cable HSLCH-JZ 5×0.75
- Cable HSLCH-JZ 3×0.75 GY
- Cable H07V-K 1×50
- Cable H07V-K 1×35
- Cable H07V-K 1×25
- Cable H07V-K 1×16
- Cable H07V-K 1×10
- Cabel H07V-K 1×1.5
- Cable H07V-K 1×6
- Cable H07V-K 1×4
- Cable H07V-K 1×2.5
- Cable H07RN-F 7G2.5
- Cable H07RN-F 7G1.5
- Cable H07RN-F 5G4
- Cable H07RN-F 5G2.5
- Cable H07RN-F 5G1.5
- Cable H07RN-F 4G16
- Cable H07RN-F 4G10
- Cable H07RN-F 4G6
- Cable H07RN-F 4G4
- Cable H07RN-F 4G2.5
- Cable H07RN-F 4G1.5
- Cable H07RN-F 3G10
- Cable H07RN-F 3G6
- Cable H07RN-F 3G4
- Cable H07RN-F 3G2.5
- Cable H07RN-F 3G1.5
- Cable H07RN-F 2X6
- Cable H07RN-F 2X4 BK
- Cable H07RN-F 2X2.5
- Cable H07RN-F 2X1.5
- Cable H05VV-F PVC 3X2.5
- Cable H05VV-F PVC 3X1.5
- Cable H05VV-F PVC 3X1.0
- Cable H05VV-F PVC 3X0.75
- Cable H05VV-F PVC 2X2.5
- Cable H05VV-F PVC 2X1,5
- Cable H05VV-F PVC 2X1,0
- Cable H05VV-F 2X0.75
- Wire H05V-K 1X1
- Wire H05V-K 1X0,75
- Wire H05V-K 1X0.5
PKZM0 — Motor Protection Circuit Breaker (Eaton Moeller Series)
The PKZM0 is a motor protection circuit breaker from the Eaton Moeller series, combining overload and short-circuit protection in a single compact device. The series includes 19 frame sizes, with a thermal protection adjustment range from 0.1 to 63 A, allowing precise selection based on the motor’s rated current.
Application Areas
PKZM0 is installed in:
• control cabinets
• motor protection and control assemblies
• motor starter systems
— wherever local motor protection is required within a single device.
The series is fully compatible with Eaton DIL contactors, making it well-suited for standard direct-on-line (DOL) and reversing starter circuits. This simplifies both new installations and modernization of existing low-voltage switchgear and industrial automation control panels (PLC/SCADA systems), enabling compact and service-friendly motor starter assemblies.
Design and Integration
The PKZM0 combines protection functions for three-phase motors against overload and short circuit within a single enclosure.
In the event of a fault:
• the device disconnects all three poles simultaneously
• restart is manual only, preventing unintended automatic restart under fault conditions
The device also provides:
• phase loss sensitivity
• ambient temperature compensation — automatically active within the range of –5 to +40 °C
A built-in test function (operated via screwdriver) allows verification of device functionality. The motor rated current is set on the front panel using a rotary adjustment dial (current setting dial) with a screwdriver.
Optional accessories include:
• auxiliary contacts
• trip indication modules
• undervoltage releases
• external rotary handles for door mounting
This allows building a complete motor protection and control unit without changing the base device platform.
Use in Technosens Projects
Technosens uses PKZM0 as a standard element for motor feeder protection in:
• control cabinet design
• branch circuit configuration
• low-voltage infrastructure systems
The device is widely implemented in standard motor starter схемах → (виправлено) circuits and has proven reliable across projects of various scales — from individual motor starters to complex process control systems.
For In-House Panel Builders
Some industrial enterprises operate their own electrical assembly departments and build control cabinets for internal use. In such cases, we supply PKZM0 and related components as standalone items tailored to specific project requirements and specifications.
At the same time, involving our engineering team at the design stage helps to avoid typical selection errors, including:
• correct current rating selection
• verification of protection selectivity
• proper coordination of the entire protection system
This expertise remains critical even when in-house assembly capabilities are available.
Because installing control cabinets alone is not sufficient — it is essential to ensure proper coordination between existing equipment and new systems so that modernization does not disrupt established production processes.
| Thermal protection current | Rated power at 380 V | Type | Part Number |
|
With rotary actuator (start control) |
|||
| 0,1…0,16 | PKZM0-0,16 | 072730 | |
| 0,16…0,25 | 0,06 | PKZM0-0,25 | 072731 |
| 0,25…0,4 | 0,09 | PKZM0-0,4 | 072732 |
| 0,4…0,63 | 0,12 | PKZM0-0,63 | 072733 |
| 0,63…1 | 0,25 | PKZM0-1 | 072734 |
| 1…1,6 | 0,55 | PKZM0-1,6 | 072735 |
| 1,6…2,5 | 0,75 | PKZM0-2,5 | 072736 |
| 2.5…4 | 1,5 | PKZM0-4 | 072737 |
| 4…6,3 | 2,2 | PKZM0-6,3 | 072738 |
| 6,3…10 | 4 | PKZM0-10 | 072739 |
| 10…12 | 5,5 | PKZM0-12 | 278486 |
| 12…16 | 7,5 | PKZM0-16 | 046938 |
| 16…20 | 9 | PKZM0-20 | 046988 |
| 20…25 | 12,5 | PKZM0-25 | 046989 |
| 25…32 | 15 | PKZM0-32 | 278489 |
| 32…40 | 20 | PKZM4-40 | 222354 |
| 40…50 | 25 | PKZM4-50 | 223555 |
| 50…58 | 30 | PKZM4-58 | 222394 |
| 58…63 | 34 | PKZM4-63 | 222413 |
| With push-button actuator (start control) | |||
| 0,1…0,16 | PKZM01-0,16 | 278475 | |
| 0,16…0,25 | 0,06 | PKZM01-0,25 | 278476 |
| 0,25…0,4 | 0,09 | PKZM01-0,4 | 278477 |
| 0,4…0,63 | 0,12 | PKZM01-0,63 | 278478 |
| 0,63…1 | 0,25 | PKZM01-1 | 278479 |
| 1…1,6 | 0,55 | PKZM01-1,6 | 278480 |
| 1,6…2,5 | 0,75 | PKZM01-2,5 | 278481 |
| 2.5…4 | 1,5 | PKZM01-4 | 278482 |
| 4…6,3 | 2,2 | PKZM01-6,3 | 278483 |
| 6,3…10 | 4 | PKZM01-10 | 278484 |
| 10…12 | 5,5 | PKZM01-12 | 278485 |
| 12…16 | 7,5 | PKZM01-16 | 283390 |
| 16…20 | 9 | PKZM01-20 | 283383 |
| 20…25 | 12,5 | PKZM01-25 | 288893 |