- SZK PH2 VDE
- SZK PH1 VDE: Phillips screwdriver PH1 with VDE insulation
- Pliers UNIFOX-C VDE
- Stripping WIREFOX 2.5
- Stripper WIREFOX 4
- Screwdriver SZS 0.4X2.5 VDE
- Screwdriver SF-SL 0.6×3.5–100
- Screwdriver SF-SL 0.4×2.5–75
- Screwdriver SF-PH2-100
- Screwdriver SZS 0.6×3.5 VDE
- Screwdriver SF-PH1-80
- Tool set SF-M
- Stripping tool WIREFOX 6SC
- Automatic stripper WIREFOX 10
- Cable stripping WIREFOX-D 28
- Electronic cutters MICROFOX SP-1
- Diagonal cutter MICROFOX-S ESD
- Cutter CUTFOX-S VDE
- Cutter CUTFOX-CD
- Cutter CUTFOX-ES
- Cutter CUTFOX 12
- CRIMPFOX CENTRUS 10S
- UT10 terminal block
- UT6 terminal block
- UT4 TWIN terminal block
- UT4 QUATTRO terminal block
- UT4 terminal block
- UT2.5 TWIN terminal block
- UK6N terminal block
- UT2.5 QUATTRO terminal block
- UT2.5 terminal block
- UK10N terminal block
- UK2.5N terminal block
- ST6 terminal block
- ST4-TWIN terminal block
- ST4-QUATTRO terminal block
- ST4 terminal block
- ST2.5-TWIN terminal block
- ST2.5 QUATTRO terminal block
- ST2.5 terminal block
- PT6 terminal block
- PT 4-TWIN terminal block
- PT 4 terminal block
- PT 2.5-TWIN terminal block
- PT 2.5-QUATTRO terminal block
- PT 2.5 terminal block
- Cable YSLYSY-JZ 18×0.75
- Cable YSLYSY-JZ 12×0.75
- Cable YSLYSY-JZ 7×0.75
- Cable YSLYSY-JZ 5×0.75
- Cable YSLYSY-JZ 3×0.75
- Cable YSLY-OZ 7×0.75
- Cabel YSLY-OZ 5×0.75
- Cable YSLY-OZ 3×0.5
- Cable YSLY-OZ 2×0.5
- Cabel YSLCY-JZ 7×0.75
- Cable YSLCY-JZ 5×0.75
- Cable YSLCY-JZ 3×0.75
- Cable HSLCH-OZ 2×0.75
- Cable HSLCH-JZ 7×0.75
- Cable HSLCH-JZ 5×0.75
- Cable HSLCH-JZ 3×0.75 GY
- Cable H07V-K 1×50
- Cable H07V-K 1×35
- Cable H07V-K 1×25
- Cable H07V-K 1×16
- Cable H07V-K 1×10
- Cabel H07V-K 1×1.5
- Cable H07V-K 1×6
- Cable H07V-K 1×4
- Cable H07V-K 1×2.5
- Cable H07RN-F 7G2.5
- Cable H07RN-F 7G1.5
- Cable H07RN-F 5G4
- Cable H07RN-F 5G2.5
- Cable H07RN-F 5G1.5
- Cable H07RN-F 4G16
- Cable H07RN-F 4G10
- Cable H07RN-F 4G6
- Cable H07RN-F 4G4
- Cable H07RN-F 4G2.5
- Cable H07RN-F 4G1.5
- Cable H07RN-F 3G10
- Cable H07RN-F 3G6
- Cable H07RN-F 3G4
- Cable H07RN-F 3G2.5
- Cable H07RN-F 3G1.5
- Cable H07RN-F 2X6
- Cable H07RN-F 2X4 BK
- Cable H07RN-F 2X2.5
- Cable H07RN-F 2X1.5
- Cable H05VV-F PVC 3X2.5
- Cable H05VV-F PVC 3X1.5
- Cable H05VV-F PVC 3X1.0
- Cable H05VV-F PVC 3X0.75
- Cable H05VV-F PVC 2X2.5
- Cable H05VV-F PVC 2X1,5
- Cable H05VV-F PVC 2X1,0
- Cable H05VV-F 2X0.75
- Wire H05V-K 1X1
- Wire H05V-K 1X0,75
- Wire H05V-K 1X0.5
VLT® AQUA Drive FC 202 from Danfoss is a specialized frequency converter designed for controlling pumps and pumping stations in water supply and wastewater treatment. It is optimized to increase energy efficiency and reduce operating costs, offering a wide range of capabilities, including water flow regulation and automatic pump cleaning to prevent blockage.
Automation of water supply and heating systems using the VLT® AQUA Drive FC 202 from Danfoss provides increased efficiency of pumping units and a significant reduction in operating costs. The FC-202 is an optimal solution for water utilities and heating networks thanks to special control algorithms developed specifically for these tasks. Ready-made algorithms minimize setup time, automatically adapting operation to changing operating conditions.
Role played in the motor control cabinet: \”heart\” of the cabinet
FC-202 opens up new automation possibilities in the following areas:
Sewage Pumping Stations (SPS)
For SPS, the FC-202 frequency converter offers a self-cleaning function that prevents the accumulation of solid particles and blocks equipment shutdowns due to clogging. This significantly reduces the amount of maintenance and emergency situations. Thanks to integration with SCADA systems via RS-485 or Modbus, operators can remotely control and monitor pump operation, making quick decisions in real time. In addition, anti-blocking algorithms increase reliability, and energy-efficient control allows saving up to 30% of electricity by optimizing pump starts and operation.
Wells and Water Lifting Systems
For water lifting, the FC-202 provides smooth starting and stopping, which eliminates water hammer, reduces mechanical stress on equipment, and extends its service life. The built-in PID controller maintains stable pressure even with variable water consumption, ensuring uninterrupted system operation. Thanks to the auto-tuning function, the frequency converter adapts the system to specific operating conditions, reducing start-up and setup costs. In addition, the FC-202 allows reducing electricity consumption by up to 40% due to optimal regulation of pump operation.
District Heating Pumps
For district heating networks, the FC-202 offers a cascade controller that automatically controls multiple pumps, optimizing their performance and reducing energy consumption. Thanks to precise temperature and pressure regulation, the system prevents overheating and underheating, ensuring maximum comfort for end users. The unique pre-alarm function allows quick response to any deviations, reducing the risk of downtime. In addition, real-time monitoring increases the efficiency of heat supply and system reliability.
Remote Control and Integration
The FC-202 frequency converter supports integration with Modbus and BACnet protocols, which allows easy connection to various automation systems for remote monitoring and control. Thanks to the current state monitoring function, the equipment warns in advance about possible problems, minimizing the risks of accidents. Event logs and energy monitoring allow analyzing the system’s operation, optimizing its efficiency. Automatic notifications also help simplify maintenance and improve operational safety.
Reliability: Increased service life due to minimized mechanical wear of motors.
Intelligent control: Built-in algorithms for water utility automation, which allow easy setup and adaptation of the system for various tasks.
Motor protection: The VFD provides protection against overloads, short circuits, and overheating, extending the life of the equipment.
Thus, the VLT® AQUA Drive FC 202 as part of a comprehensive automation system significantly increases the efficiency of pump equipment management, reduces energy and maintenance costs, and ensures reliable network operation.
Operating Manual 0.25 – 90 kW
Operating Manual 110 – 800 kW
Design Manual 0.25 – 90 kW
Design Guide 110-800 kW
| Type | Model code | Power | Current rating | Protection | Phases | Mains voltage | Width*Height*Depth |
| FC-202PK37T4 | 131B8870 | 0.37 kW | 1.3 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202PK75T4 | 131B8886 | 0.75 kW | 2.4 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202P1K5T4 | 131B8649 | 1.5 kW | 4.1 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202P2K2T4 | 131B8903 | 2.2 kW | 5.6 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202P3K0T4 | 131B8912 | 3 kW | 7.2 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202P4K0T4 | 131B8920 | 4 kW | 10 А | IP20 | 3 | 380-480 В ± 10% | 268х90х205 мм |
| FC-202P5K5T4 | 131B8940 | 5.5 kW | 13 А | IP20 | 3 | 380-480 В ± 10% |
268х130х205 мм
|
| FC-202P7K5T4 | 131B8650 | 7.5 kW | 16 А | IP20 | 3 | 380-480 В ± 10% |
268х130х205 мм
|
| FC-202P11KT4 | 131F6637 | 11 kW | 23 А | IP20 | 3 | 380-480 В ± 10% |
350х165х250 мм
|
| FC-202P15KT4 | 131F6641 | 15 kW | 32 А | IP20 | 3 | 380-480 В ± 10% |
350х165х250 мм
|
| FC-202P18KT4 | 131F6645 | 18.5 kW | 37.5 А | IP20 | 3 | 380-480 В ± 10% |
399х165х250 мм
|
| FC-202P22KT4 | 131F6765 | 22 kW | 44 А | IP20 | 3 | 380-480 В ± 10% |
520х230х242 мм
|
| FC-202P30KT4 | 131F6770 | 30 kW | 61 А | IP20 | 3 | 380-480 В ± 10% |
520х230х242 мм
|
| FC-202P37KT4 | 131F6775 | 37 kW | 73 А | IP20 | 3 | 380-480 В ± 10% |
520х230х242 мм
|
| FC-202P45KT4 | 131F6650 | 45 kW | 90 А | IP20 | 3 | 380-480 В ± 10% |
550х308х233 мм
|
| FC-202P55KT4 | 131F6654 | 55 kW | 106 А | IP20 | 3 | 380-480 В ± 10% |
550х308х233 мм
|
| FC-202P75KT4 | 131F6658 | 75 kW | 147 А | IP20 | 3 | 380-480 В ± 10% |
660х370х333 мм
|
| FC-202P90KT4 | 131F6663 | 90 kW | 177 А | IP20 | 3 | 380-480 В ± 10% |
660х370х333 мм
|
| FC-202N110T4 | 134F0366 | 110 kW | 212 А | IP20 | 3 | 380-480 В ± 10% |
909х250х375 мм
|
| FC-202N132T4 | 134F0368 | 132 kW | 260 А | IP20 | 3 | 380-480 В ± 10% |
909х250х375 мм
|
| FC-202N160T4 | 134F0371 | 160 kW | 315 А | IP20 | 3 | 380-480 В ± 10% |
909х250х375 мм
|
| FC-202N200T4 | 134F0372 | 200 kW | 395 А | IP20 | 3 | 380-480 В ± 10% |
1122х350х375 мм
|
| FC-202N250T4 | 134F0373 | 250 kW | 480 А | IP20 | 3 | 380-480 В ± 10% |
1122х350х375 мм
|
| FC-202N315T4 | 134F4192 | 315 kW | 600 А | IP20 | 3 | 380-480 В ± 10% |
1122х350х375 мм
|